research article

Influence of Storage Media on Color Stability of Different Resin Composites as Determined by ΔE and ΔE00

Emilie Bétrisey1*, Enrico Di Bella2, Ivo Krejci1, Stefano Ardu1

1Division of Cariology and Endodontology, University of Geneva, Geneva, Switzerland

2Department of Economics and Buisness Studies, University of Genoa, Genoa, Italy

*Corresponding author: Emilie Bétrisey, DMD Maître Assistant, Division of Cariology and Endodontology, University of Geneva, 1 rue Michel-Servet, 1211 Geneva, Switzerland. Tel: +41223794177; Email: emilie.betrisey@unige.ch

Received Date: 08 March, 2018; Accepted Date: 21 March, 2018; Published Date: 29 March, 2018

Citation: Bétrisey E, Bella ED, Krejci I, Ardu S (2018) Influence of Storage Media on Color Stability of Different Resin Composites as Determined by ΔE and ΔE00Dent Adv Res 3: 151. DOI: 10.29011/2574-7347.100051

Abstract

Objective: To evaluate the color stability of 3 different resin composites when exposed to storage in water, air or artificial saliva.

Materials and Methods: Initial color of 81 specimens was assessed by a calibrated reflectance spectrophotometer over a black as well as a white background. Specifically, 9 disc shaped specimens made out of 3 resin composite materials were kept in distilled water, air and artificial saliva (Glandosane) at 37°C. After a storage period of 4 weeks, spectrophotometric measurements were repeated and the color changes calculated by means of ΔE and ΔE00.

Results: When analysed over a white background, median ΔE values varied from 0.6 (Filtek Supreme Dentin/water) to 7.1 (Filtek Supreme Enamel/Glandosane). When analysed over a black background median ΔE values varied from 0.4 (Filtek Supreme Dentin/water) to 5.0 (Filtek Supreme Enamel/Glandosane). When analysed over a white background, median ΔE00 values varied from 0.4 (Filtek Supreme Dentin/water) to 4.6 (Filtek Supreme Enamel/Glandosane). When analysed over a black background median ΔE00 values varied from 0.4 (Filtek Supreme Dentin/water) to 4.6 (Filtek Supreme Enamel/Glandosane). Statistical analysis performed by means of ANOVA and Fisher’s LSD post hoc tests showed differences between groups. The correlation between ΔE and ΔE00 was 99.09% and 99.65% over black and white background, respectively.

Conclusion: Within the limits of the present study, storage media significantly influenced color stability of resin composites.

1.       Introduction

Restorative composite resins are commonly used materials for esthetic direct restorations. Knowing that these materials are not inert and undergo changes over time especially in respect to their color, it is interesting to assess the influence of different storage media regarding this parameter. Artificial saliva may be considered the gold standard that simulates oral environment. However, other alternatives may be considered such as distilled water or simply air. So far, few articles in literature have investigated the influence of storage media on color stability of resin composites [1,2] and no consensus exists on this topic.

Discoloration can be evaluated objectively with various instruments or subjectively by means of human eyes. Since instrumental measurements eliminate the subjective interpretation of visual-color comparison, spectrophotometers and colorimeters have been used to quantify color changes in dental materials [3,4]. One of the most commonly used methods to assess composites’ color changes is the reflectance spectrophotometry with the CIE (Comission Internationale de l'Eclairage) L*a*b* color system which has been widely used in the literature [5,6]. The color coordinates of the CIELAB system are L*, representing the value and ranging from 0 (black) to 100 (white). a* and b* are chromaticity coordinates along the red-green (positive value indicates red, negative indicates green) and yellow-blue axes (positive value indicates yellow; negative indicates blue), respectively.

The working hypothesis of this study was therefore to test the color stability of different composite brands under the influence of different storage media by using a spectrophotometer and by determining their ΔE as well as their ΔE00. The null hypotheses were that storage media have no significant effect on color stability and that ΔE and ΔE00 are highly correlated.

2.       Materials and Methods

Eighty-one disc-shaped specimens with a diameter of 10 mm and 1.0 +/- 0.05 mm thickness as verified by means of a digital calliper (digit-cal capaμsystem, S/N 8R565806, TESA, Renens, Switzerland) were made of three different composite materials (Table 1) by gently pressing a defined amount of material between two glass slides [7]

The composite resins specimens were light cured for 20 s using a 1100mW/cm2 LED light curing unit (Bluephase, S/N 1523817, Ivoclar Vivadent, Schaan, Liechtenstein). Specimens’ color measurements L*a*b* were assessed by quantitative numerical measurement approach, using a calibrated reflectance spectrophotometer (Spectro Shade Handy Dental Type 713000, S/N HDL2891, Medical High Technologies, Arbizzano di Negar, Italy).

This device has a build-in aiming routine that enables a reproducible positioning perpendicular to the sample’s surface to ensure equal measurement conditions for all the evaluated specimens. Specifically, this device is equipped with a D65 light source (6500°K) that is converted into monochromatic light by means of a grating. This light is splinted in order to have each specimen illuminated at the same time from two sides at 45° angle. The reflected light is directed at 0° on both the system’s two detector areas (both 18 x 13 mm2). One detector is a color CCD chip that generates the color video image. The other, black and white CCD detector records the spectrophotometric data. Polarization filters allow eliminating surface gloss. The data is stored in a proprietary image file format which is used to create detailed CIE L*a*b* data.

In this experiment CIE L*a*b* measurements of each specimen were performed over both white (WB) (L*=92.6, a*=-1.2, b*=2.9) and black (BB) (L*=1.6mm, a*= 1.2, b*=-1.0) background made of plasticized paper [8].

After recording the initial spectrophotometric measurement of the samples (t0), they were randomly divided in 3 groups (27 samples per group) and stored as follows: dry storage (Group 1), artificial saliva (Glandosane) (Group 2) and distilled water (H2O) (Group 3) (Table 2). The specimens were left for a period of 4 weeks at constant temperature of 37°C in an incubator (INP-500, Memmert GmbH & Co.KG, Schwabach, Germany) in the absence of light. Glandosane and H2O were changed every 7th day to avoid bacteria or yeast growth [9].

After storage, spectrophotometric measurements were performed (t4) and ΔE (t0-t4) and ΔE00 (t0-t4) were calculated according to the classic formulas:


For ΔE and ΔE00 two-way ANOVA tests were run to check on significant color differences. Fisher’s LSD post hoc test was than run to check on differences between groups.

3.       Results

The ΔE and ΔE00 values between t0 and t4 varied depending on the composite brand and the storage media (Figure 1,2). Filtek Supreme Dentin in water showed the lowest median color changes (ΔE = 0.6 (WB) / 0.4 (BB); ΔE00 = 0.4 (WB) / 0.4 (BB)) while Filtek Supreme Enamel in Glandosane showed the highest median color changes (ΔE = 7.1 (WB) / 5.0 (BB); ΔE00 = 4.6 (WB) / 4.6 (BB)).

Two-way ANOVA test confirmed that all storage media played a significant role (p-values < 0.001) in color change. The interaction between composite and storage media was significant too. In particular, artificial saliva (Glandosane) was by far the liquid that generated the highest color variations (Fisher LSD post-hoc tests are illustrated in Tables 3 and 4 for ΔE and ΔE00). No significant difference was found between air and H2O for all composites except for Tetric Bulk Fill due to a higher color change in H2O especially with a white background. The correlation coefficient for ΔE and ΔE00 was 0.9909 and 0.9965 over black and white background, respectively (Figure 3,4).  Both ΔE and ΔE00 led to the same statistical conclusions.

4.       Discussion

The evaluation of color differences can be performed by means of two techniques: the subjective visual method or the objective instrumental method. Instruments such as colorimeters or spectrophotometers have been developed to detect small differences that might be imperceptible to the human eye [10]. In this study, a spectrophotometer was used to avoid subjective bias [7,11].

Nowadays several color notation systems are available but the most used one for dental restorative materials have been in the last decades the CIELAB [12] that is why we decided to adopt this system in our experiment. Due to the imperfections of the CIELAB system, several advanced color-difference formulae were developed. The most recent one is the CIE 2000 or CIEDE2000, officially recommended as the new CIE color difference equation for dental purposes [13]. The new CIEDE2000 formula includes three weighting functions: lightness (new formula), chroma (adopted from CIE94) and hue (new formula), with the arithmetic mean of a pair of specimens used for calculating all weighting functions instead of the geometric mean [14]. In order to see if significant differences could be detected depending on the CIE system both delta E (ΔE and ΔE00) were calculated and statistically analyzed, giving the same conclusions. This was witnessed by the high correlation coefficient obtained in this study for the two delta E both on black and white background. These findings are in accordance with previous studies [15,16].

Concerning the preparation method, we decided not to polish our samples. This was done in order to standardize and to mimic the worst-case clinical situation where a composite is polymerized through a mylar strip without any finishing/polishing as might be the case in Class III or Class IV restorations. It was described in literature that covering the composite surface with a celluloid strip [17] leads to a smooth uppermost resin-rich layer with less filler content, thus more prone to coloration. The relatively high resin content and its vulnerability to water uptake have been indicated as possible reasons for higher discoloration [18,19] as water absorbed by the polymer matrix may cause matrix-filler debonding or even hydrolytic degradation of the filler itself [20]. Polishing eliminates the resin-rich surface layer [21], but it can also introduce variables that are difficult to control as shown in a recent study where surface roughness of esthetic restorative materials influenced the color coordinates [22]. To avoid bias through polishing and to simulate the most extreme but clinically relevant situation, no polishing of the surface was performed. The decision of 20 seconds polymerization was made in order to provide the same energy to all the specimens.

Concerning color stability of resin composites, literature suggests that they are not chemically inert, interacting with the storage media [10,23]. Furthermore, even storage time has been shown to have a significant influence on color stability [1]. Commonly in composite staining studies, artificial saliva, water or dry storage are the negative control [1,3,5,7,16,23], that is why we decided to experience if any statistical difference could be found in between the three-storage media. When exposed to their natural environment in the oral cavity, composite resin restorations are in constant contact with moisture. The present study tested the relationship between storage medium and the composite itself. The same behavior pattern was found independently of the composite used or the background. All composite materials of the dry storage group experienced a slight color change, likely due to post-polymerization of the material. On the other hand, artificial saliva is the medium inducing the higher color change.

The pH of Glandosane (pH 5.75) is in the range of normal saliva pH but in the lower portion. This choice has been made in order to mimic the clinical conditions of carious patients who usually have a lower saliva pH [24, 25]. Furthermore, Batra et al. [26] have reported that acidic media are responsible of surface degradation and thus induce ΔE changes.

Furthermore, artificial saliva contains conservators that might induce a difference comparing with distilled water. Human saliva contains mucins and enzymes. Several studies have shown that Cholesterol Esterase (CE) and Pseudocholinesterase (PCE) could degrade composite resins [27-29]. Under this light, it might be expected that results of color-stability tests for resin composites performed in vitro with artificial saliva could show some discrepancy with respect to the in vivo situation where values could be worsened. However, to perform in vitro studies, artificial saliva might be used as control because it closer simulates oral environment and causes statistical color variation when compared to distilled water and air.

It can be of interest even to analyze the amount of color change and to check if it is clinically relevant or just noticeable only by mechanical devices such as spectrophotometer or colorimeters.

On this purpose Ghinea [30] and colleagues attempted to determine the magnitude of color change that can be considered acceptable for 50% of observers (50:50%acceptability threshold) for color difference formulas. The authors used TSK Fuzzy Approximation for determining acceptability thresholds and reported 2.23 for the CIEDE2000 formula as the key value. In our study these values are obtained by all resin composite tested only when put in contact with Glandosane. On the other hand, all the other storage media induced changes which were always below the so called “acceptable level”.

Concerning the behavior of the different materials tested several general considerations related to their compositions can be done. Tetric Evo Ceram Bulk Fill when stored in water, showed the highest color change. A possible explanation could be due to a higher conversion rate than Filtek Supreme. Tetric Bulk fill, in fact, contains not only camphorquinone but also even Ivocerin that increases conversion rate. Moreover, his higher degree of translucency could influence positively the light transmission and further enhance the degree of polymerization.

In Filtek Supreme, camphorquinone is used as the main photoinitiator. Its color is yellow and it becomes colorless when completely polymerized. On the other hand, aging process of resin composite cause a yellow shift of the material. Therefore, a non-complete polymerization of Filtek could have act as bias of the final result obtained. Furthermore, the slightly higher translucency of Filtek Enamel (30%) compared to Filtek Dentin (17%) could have allowed a better conversion rate of Filtek Supreme Enamel causing higher color change when compared with the results obtain with Filtek Supreme Dentin. This fact could be the explanation of the higher color difference obtained for Filtek supreme Enamel if compared to the dentin shade of the same manufacturer.

Further interpretations of the obtained results are not possible because manufacturers do not reveal the exact composition of their resin composite materials. Further study made out of resins where all components and their concentrations are known are suitable in order to better understand resin composite behaviors. 

5.       Conclusion

Within the limits of the present study, storage media significantly influenced color stability of the composite resins tested. ΔE and ΔE00 were highly correlated and obviously led to the same statistical conclusions. The null hypothesis that different conservation media have no effect on the color stability of composite resins at different times was rejected. More studies are needed to confirm these findings.

6.       Declaration of Interest: none


Figure 1: ΔE values box-plot by composites.



Figure 2: ΔE00 box-plot by composites.



Figure 3: ΔE vs ΔE00 (Black background).



Figure 4: ΔE vs ΔE00 (White background).

Materials

Manufacturer

Shade

Batch Nbr.

Matrix composition*

Fillers composition*

Filtek
Supreme XTE
Enamel

3M-ESPE,
St.Paul, MN,
USA

Enamel A2

N483889

Bis-GMA, UDMA,
Bis-EMA,
TEGDMA,
PEGDMA

Silica, aggregated
zirconia (63 vol%, 78
wt%

Filtek
Supreme XTE
Dentin

3M-ESPE,
St.Paul, MN,
USA

Dentin A2

N502353

Bis-GMA, UDMA,
Bis-EMA,
TEGDMA,
PEGDMA

Silica, aggregated
zirconia (63 vol%, 78
wt%

Tetric
EvoCeram
®
Bulk Fill

Ivoclar
Vivadent,
Schaan,
Liechtenstein

IVA

S21120

Bis-GMA, Bis-
EMA, UDMA (21%
of the mass)

Barium aluminium
silicat glass,
yttermium fluoride,
mixed oxide (61 vol%
and 17% isofillers,
77wt% )

* reported by the manufacturers

Bis-EMA: ethoxylated bisphenol-A-glycidyldimethacrylate, Bis-GMA: bisphenol-A-glycidyldimethacrylate, PEGDMA: poly(ethylene glycol) dimethacrylate, TEGDMA: triethylene glycol dimethacrylate, UDMA: urethane dimethacrylate

 

Table 1: List of materials evaluated.

 

Actives ingredients

potassium chloride, sodium chloride, magnesium chloride, calcium chloride, potassium
diphosphate, sodium carboxymethylcellulosa, sorbitol.

Excipients: Conserv

 

sorbic acid (E 200), sodium benzoate (E 211), Aqua ad solutionem et Propellentia ad
Aerosolum pro 1 g

 

Table 2: Composition of Glandosane (Helvepharm AG, Frauenfeld, Switzerland).

 

White Background

Black Background

Filtek Supreme Dentin

Filtek Supreme Dentin

 

AIR

H20

 

AIR

H20

H20

0.999

-

H20

0.524

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

Filtek Supreme Enamel

Filtek Supreme Enamel

 

AIR

H20

 

AIR

H20

H20

0.963

-

H20

0.456

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

Tetric Bulk Filled

Tetric Bulk Filled

 

AIR

H20

 

AIR

H20

H20

<0.001

-

H20

0.018

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

 

Table 3: ΔE Fisher’s LSD post-hoc test p-values.

 

White Background

Black Background

Filtek Supreme Dentin

Filtek Supreme Dentin

 

AIR

H20

 

AIR

H20

H20

0.191

-

H20

0.254

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

Filtek Supreme Enamel

Filtek Supreme Enamel

 

AIR

H20

 

AIR

H20

H20

0.811

-

H20

0.716

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

Tetric Bulk Filled

Tetric Bulk Filled

 

AIR

H20

 

AIR

H20

H20

<0.001

-

H20

0.004

-

Glandosane

<0.001

<0.001

Glandosane

<0.001

<0.001

 

Table 4: ΔE00 Fisher’s LSD post-hoc test p-values.

  1. Uchimura JY, Sato F, Bianchi G, Baesso ML, Santana RG, et al. (2014) Color stability over time of three resin-based restorative materials stored dry and in artificial saliva. J Esthet Restor Dent 26: 279-287.
  2. Domingos PA, Garcia PP, Oliveira AL, Palma-Dibb RG (2011) Composite resin color stability: influence of light sources and immersion media. J Appl Sci 19: 204-211.
  3. Okubo SR, Kanawati A, Richards MW, Childress S (1998) Evaluation of visual and instrument shade matching. J Prosthet Dent 80: 642-648.
  4. Asmussen E (1983) Factors affecting the color stability of restorative resins. Acta Odontol Scand 1: 11-18.
  5. Dietschi D, Campanile G, Holz J, Meyer JM (1994) Comparison of the color stability of ten new-generation composites: an in vitro study. Dent Mater 10: 353-362.
  6. Seghi RR, Johnston WM, O'Brien WJ (1986) Spectrophotometric analysis of color differences between porcelain systems. J Prosthet Dent 56: 35-40.
  7. Ardu S, Braut V, Gutemberg D, Krejci I, Dietschi D, et al. (2010) A long-term laboratory test on staining susceptibility of esthetic composite resin materials. Quintessence Int 41: 695-702.
  8. Ardu S, Braut V, Di Bella E, Lefever D (2014) Influence of background on natural tooth colour coordinates: an in vivo evaluation. Odontology 102: 267-271.
  9. Betrisey E, Krejci I, Di Bella E, Ardu S (2016) The influence of stratification on color and appearance of resin composites. Odontology 104: 176-183.
  10. Chu SJ, Trushkowsky RD, Paravina RD (2010) Dental color matching instruments and systems. Review of clinical and research aspects. J Dent 38: 2-16.
  11. Kim-Pusateri S1, Brewer JD, Davis EL, Wee AG (2009) Reliability and accuracy of four dental shade-matching devices. J Prosthet Dent 101: 193-199.
  12. Commission International de l’Eclairage (CIE) (1986) Colorimetry. (2nd edition). CIE publication No. 15.2. Vienna: Central Bureau of the CIE.
  13. Luo MR, Cui G, Figg B (2001) The development of the CIE 2000 colour difference formula: CIEDE2000. Col Res Appl 26: 340-350.
  14. Paravina RD, Kimura M, Powers JM (2005) Evaluation of polymerization-dependent changes in color and translucency of resin composites using two formulae. Odontology 93: 46-51.
  15. Lee YK (2005) Comparison of CIELAB DeltaE(*) and CIEDE2000 color-differences after polymerization and thermocycling of resin composites.  Dent Mater 21: 678-682.
  16. Ardu S, Duc O, Di Bella E, Krejci I (2017) Color stability of recent composite resins. Odontology. 105: 29-35.
  17. Hachiya Y, Iwaku M, Hosoda H, Fusayama T (1984) Relation of finish to discoloration of composite resins. J Prosthet Dent 52: 811-814.
  18. VON Fraunhofer JA (1971) The surface hardness of polymeric restorative materials. Br Dent J 130: 243-245.
  19. Okazaki M, Douglas WH (1984) Comparison of surface layer properties of composite resins by ESCA, SEM and X-ray diffractometry. Biomaterials 5: 284-288.
  20. Soederholm KJ, Zigan M, Ragan M, Fischlschweiger W, Bergman M (1984) Hydrolitic degradation of dental composites. J Dent Res 63: 1248-1254.
  21. Gordan VV, Patel SB, Barrett AA, Shen C (2003) Effect of surface finishing and storage media on bi-axial flexure strength and microhardness of resin-based composite. Oper Dent 28: 560-567.
  22. Lee YK, Yu B, Lee SH, Cho MS, Lee CY, et al. (2010) Variation in instrument-based color coordinates of esthetic restorative materials by measurement method: a review. Dent Mater 26: 1098-1105.
  23. Gregor L, Krejci I, Di Bella E, Feilzer AJ, Ardu S (2016) Silorane, ormocer, methacrylate and compomer long-term staining susceptibility using ΔE and ΔE00 colour-difference formulas. Odontology 104: 305-309.
  24. Basch Y, Peretz B (2013) Salivary pH levels and caries among siblings and parents within families. J Clin Pediatr Dent 38: 129-132.
  25. Cunha-Cruz J, Scott J, Rothen M, Mancl L, Lawhorn T, et al. (2013) Salivary characteristics and dental caries: evidence from general dental practices. J Am Dent Assoc 144: 31-40.
  26. Batra R, Kataria P, Kapoor S (2016) Effect of Salivay pH on Color Stability of Different Flowable Composite -  A Prospective In-vitro Study. J Clin Diagn Res 10: 43-46.
  27. Lee YK, Lim BS, Powers JM (2004) Color changes of dental resin composites by a salivary enzyme. J Biomed Mater Res Appl Biomater 70: 66-72.
  28. Munksgaard EC, Freund M (1990) Enzymatic hydrolysis of (di) methacrylates and their polymers. Scand J Dent Res 98: 261-267. 
  29. Santerre JP, Shajii L, Tsang H (1999) Biodegradation of commercial dental composites by cholesterol esterase. J Dent Res 78: 1459-1468.
  30. Ghinea R, Pérez MM, Herrera LJ, Rivas MJ, Yebra A, et al. (2010) Color difference thresholds in dental ceramics. J Dent 38: 57-64.

© by the Authors & Gavin Publishers. This is an Open Access Journal Article Published Under Attribution-Share Alike CC BY-SA: Creative Commons Attribution-Share Alike 4.0 International License. With this license, readers can share, distribute, download, even commercially, as long as the original source is properly cited. Read More.

Dentistry: Advanced Research

rumus slot mahjongrtp slot gacorfitur slot mahjong winsrekomendasi slot pragmartp live slotpola gates of gatotkacaapk cheat slotzeus godwrath maxwinmitra slot dana resmihabanero anti gagalserver kamboja gacordaftar link togelslot pg mahjongtrik pola zeus x500slot gacor mudah menangslot mahjong pragmaticpola trik slot mahjongrtp fortune dragonrtp slot speed winnerslot kamboja mahjong waystrik mantap slot olympusnaga hitam mahjongslot tergacor mahjongtrik jitu cuan mahjongpola slot mahjong winsrtp tinggi pragmaticslot mahjong onlineslot gacor hari inislot bonanza gacorfreebet mahjong winsserver jp rtp tinggigame resmi pragmatic terbaiktaktik efektif mahjongpola mahjong rekomendasi googleaztec gems boskututorial mahjong ways2starlight princess hari inipola starlight princessrtp fortune tigerrtp pg softrtp starlight princesstrik mahjong waysperkalian x5000 banditoslot mahjong waysslot terbaik olympusslot gates of olympusdaftar slot dana maxwinbocoran pola olympusmaxwin slot bonanzabocoran rtp tinggislot samurai codemetode slot starlightslot zeusrtp slot gacor pragmaticrtp slot pg softcara menang slot onlinescatter slot mahjongslot gacor server luar rekomendasi link olympusgerbang gatot kacartp kakek olympusslot gacor andalanrtp slot pgslot mahjongslot mahjong server jepangperkalian besar starlightrtp ways of qilinslot terbaik mahjongmahjong bulan mudastrategi permainan pragmaticcheat engine gacorjackpot auto cuanmahjong mekanik tinggitrik slot mahjongtips main slotslot server thailandpola mahjong unguslot gacor menangpg soft scatterslot olympusbocoran togel terpercayaamantotorm1131aman toto