Unwinding the Umbilical Cord in Evaluating Pregnancy Outcome at a Tertiary Hospital
Mohammed Khizer Razak1, Deepika Meena2*, Guljhari Lal Meena1
1Department
of Radio-Diagnosis, Sardar Patel Medical College, Bikaner, Rajasthan, India
2Department of Dentistry, Sardar Patel Medical College, Bikaner, Rajasthan, India
*Corresponding author: Deepika Meena, Department of Dentistry, Sardar Patel Medical College, Bikaner, Rajasthan-334001, India. Tel: +919413143709; Email: meenabkn@yahoo.co.in
Received Date: 21 November, 2017; Accepted Date: 29 November, 2017; Published Date: 07 December, 2017
Citation: Razak MK, Meena D, Meena GL (2017) Unwinding the Umbilical Cord in Evaluating Pregnancy Outcome at a Tertiary Hospital.J Nucl Med Radiol Imaging: JNMRI-105.DOI:10.20911/JNMRI-105/100005
1. Abstract
1.1. Aims & Objectives: To assess the relationship of ultrasound measurements of cord thickness, cross sectional area and coiling index in the second trimester (18 to 24 weeks) with perinatal outcome.
1.2. Material & Methods: This study was conducted on 100 pregnant women visiting the obstetric outpatient department at Prince Bijey Singh Memorial hospital, Bikaner, Rajasthan during the period of November 2016 to November 2017, for antenatal check-up and scheduled to deliver in the same hospital. The cord thickness, cross sectional area and antenatal coiling index were studied by ultrasound during 18-24 weeks of gestation. The study to assess the relationship between these parameters and perinatal outcome in relation to the gestational age at the time of delivery, mode of delivery, birth weight of the baby, Meconium Stained Amniotic Fluid (MSAF) and NICU admission of the baby was carried out and statistically compared.
1.3. Results: There was a significant correlation between the hypo coiled cord (aUCI less than 10th percentile) with the preterm labor (p value 0.035) and low birth weight (p value<0.001).There was a significant correlation between the hyper coiled cord (aUCI more than 90th percentile) with MSAF (p value<0.001). There was a statistically significant correlation between umbilical cord thickness and cross-sectional area with preterm labor (p values 0.002 and 0.012), low birth weight (p values <0.001 and <0.001) and NICU admission (p values 0.005 and <0.001) respectively.
1.4. Conclusion: Hypo coiled cords are associated with spontaneous preterm labor and low birth weights while hyper coiled cords are associated with MSAF. The umbilical cord thickness and cross-sectional area are also associated with preterm labour, low birth weights and NICU admission of the baby.
2. Keywords: Area; Coiling; Prenatal; Thickness; Ultrasound
1. Introduction
The umbilical cord is the life line of the fetus as it provides the nutrients, oxygen and fluids necessary for life in utero. The protection of the cord is provided by the Wharton’s jelly, the amniotic fluid and the helical pattern or the coiling of the umbilical vessels [1]. The cord and its constituent’s tissues, an outer layer of amnion, porous Wharton’s jelly, two arteries and one vein are designed to provide and maintain blood flow to the developing fetus. Cord represents the most vulnerable link between the fetus and the mother, since it lies freely in the amniotic fluid and may be easily damaged [2].
Coiling
makes the umbilical cord flexible, strong and at the same time provides
resistance to external forces that could compromise blood flow to the fetus [3] coiling property of the umbilical cord was first
described by Berengaria’s in 1521 [4]. In 1954,
umbilical coiling was first quantified by Edmonds. He divided the total number
of coils by the umbilical cord length in centimeters and called it “the index
of twist”. He suggested positive and negative scores to clockwise and
anticlockwise coiling respectively [5]. Later,
Strong et.al, simplified these by eliminating directional scores (Figure 1) and named it “The umbilical cord coiling
index” [6].
Hypo coiled cords are mainly associated with increased incidence of structural and chromosomal abnormalities, fetal anomalies [7], abnormal insertion [8-9], intrauterine death [10-12], preterm delivery [13-15], operative delivery for fetal distress and low APGAR score [16] which marks the underlying intrinsic abnormal development and increased risk of acute reduction in blood flow due to kinking [17-19].
Hyper coiling of the cord was also associated with IUGR, intrapartum fetal acidosis and asphyxia, vascular thrombosis and cord stenos is by predisposing to compression mediated flow reduction and possible predisposition [20] to development of fetoplacental vascular thrombosis [21]. Thus, it appears that presence of abnormal coiling indicates a chronic state established in early gestation that may have acute and chronic effects on the fetus [22].
The detection of umbilical cord cross sectional (Figure 2) area<10th percentile in 2nd trimester was associated with 12-fold increased risk of subsequent delivery of small for gestational infants (Figure 3). An association between the small diameter of the umbilical cord and the presence of oligohydroamnios, me conium stained amniotic fluid or both or without low APGAR scores is found (Figure 4) [23] marked segmental thinning of the umbilical cord vessels is an infrequent finding of undetermined origin. Its significance may be associated with increased congenital anomalies and prenatalproblems (Figure 5) [24].
2. 2. Material & Methods
The present prospective observational study was conducted in Prince Bijey Singh memorial hospital (P.B.M), Bikaner, Rajasthan to correlate the antenatal assessment of the umbilical cord thickness, cross sectional area and coiling index at 18-24 weeks of gestation and perinatal outcome in relation to gestational age at the time of delivery, mode of delivery, birth weight of the baby, APGAR score, MSAF and NICU admission of the baby.
·
Study design : Prospective
observational study
·
Study period : November
2016 to November 2017
· Statistical method : T test
The present study is conducted on 100 pregnant women referred to the department of Radio diagnosis, outpatient department for antenatal assessment between 18-24 weeks from the department of Obstetrics and scheduled to deliver at P.B.M hospital, Bikaner, Rajasthan Between November 2016 to November 2017.
3. Method of Collection of Data
All booked consenting pregnant women attending the Radio Diagnosis O.P.D for regular antenatal fetal surveillance between 18-24 weeks were included in the study. All sonographic examination was performed by a single radiologist using standard USG machine with color Doppler (HitachiAlokaProsound Alpha A7) and convex transducer of 3.5 to 5.0 MHz
3.1. Inclusion Criteria
1.
Singleton pregnancy irrespective of
parity.
2.
Reliable gestational age between 18-24
weeks at the time of sonography.
3.
Normal amniotic fluid.
4. Presence of three vesseled umbilical cords.
3.2. Exclusion Criteria
1.
Multiple pregnancies.
2.
Fetal congenital anomaly.
3.
Maternal complications like diabetes
mellitus, hypertension that could interfere with fetal growth.
4.
If the patient could not be followed
till delivery for any reason.
5. Any umbilical cord or placental anomaly.
4. Results
100 women who fulfilled the inclusion criteria were taken in the study. The umbilical cord thickness, cross sectional area and coiling index were calculated during 18-24 weeks of gestation and women were followed till delivery and the perinatal outcome was correlated with regards to gestational age at delivery, mode of delivery, birth weight, APGAR score at 1st and 5th minute, presence of MSAF and NICU admission of the baby (Table1, Graph1).
The number of patients with umbilical cord thickness <7mm are 18 (18%), those between 7-12 mm are 71 (71%) and cord thickness ≥12 mm is 11 (11%).
The cross-sectionalarea (Table 2 & Graph 2) of the umbilical cord less than 20 mm2 is seen in 17 (17%); those between 20-30mm2 is seen in 47 (47%) and more than 30mm2 in 36 (36%) patients.
The
women included in the study were in the age group of 18-40 years. Majority of
the women were in the age group of 20-30(88%), mean age group being 22.78±3.36 years. There was no statistical significance (Table 3 and Graph 3).
aUCI of less than 0.3 is present in 16 (16%) patients; between 0.3 to 0.6 in 66 (66%) patients and more than 0.6 is present in 18 (18%) patients.Out of the 100 patients, 56% women were primigravida and 44% are multigravida. The cord thickness of less than 7 mm was observed in 18%, between 7-12 mm it was observed in 71% and more than 12 mm of cord thickness was observed in 11%. The mean cord thickness being 8.81±2.14 mm, which correlates with the study conducted by Morteza Tahamasebi and Aligambari R (10.54mm). The cross-sectional area of the umbilical cord was less than 20mm2 in 17%, between 20-30mm2 in 47% and more than 30mm2 in 36%. The mean cross-sectional area in our study is 25.03±7.48 mm2. This correlates with the study conducted by Degani et al. (29±5mm2). In our study, aUCI<0.3 was present in 16%, 0.3-0.6 in 66% and more than 0.6 in 18%. The mean aUCI was 0.44±0.15. It was similar to the studies conducted by Morteza Tahamasebi [9], Aligambari R [8] and Sharma B et al. [1]. Out of the 100 patients studied 10% were hypo coiled, 11% hyper coiled and 79% patients were norm coiled. Out of several similar studies, the coiling distribution in our studies correlates with the study by Sharma B. et al [25]. In our study, 6% of three patients delivered before 37 weeks of gestation, 78% women delivered at term (37-40 weeks of gestation) and 16% patients delivered between 40-41 weeks [25]. The mean cord thickness in the preterm delivered patients is 6.33±1.51 mm while in term delivery patients it is 9.05±2.07 mm. The p value is 0.002 and there is a statistically significant correlation between the cord thickness and preterm delivery. Thin cords are associated with preterm delivery (Table 4, Graph 4).
The
mean cross-sectional area of the umbilical cord in patients delivered preterm
is 17.67±7.23mm2 while
in the term delivery patient it is 22.50±7.28 mm2 and the p value is 0.012. So, there is a
statistically significant correlation between the umbilical cord cross
sectional area and gestational age at delivery. As the cord cross sectional
area reduces there is increased risk of preterm delivery.
Cord
thickness of less than 7 mm and cross-sectional area of the cord has a
statistically significant relation with NICU admissions. Pvalue being 0.005 and
0.001 but aUCI has no statistical correlation with NICU admissions’ value being
0.556 (Table 5, Graph 5).
Cord thickness and cross-sectional area has no statistical correlation with MSAF. But hyper coiled cord has a statistically significant correlation with MSAF.P value being <0.001.
Pre-term
delivery was present in 20% of the hypo coiled women and 5.15% of the norm
coiled women. No preterm delivery was observed in the hyper coiled group. The
mean aUCI is 0.31±0.15 in preterm patients and
0.45±0.15 in term patients. There was a
statistically significant correlation between the hypo coiled cords and preterm
delivery, the p value being 0.035 (Table 6 and Graph 6). Thus, hypo coiled
cords were associated with preterm delivery.
Umbilical cord thickness, cross sectional area and aUCI all have statistically significant correlation with birth weight. P values being <0.001 for all the three
In all these studies there is a significant correlation between Hypo coiling and preterm delivery. Our study correlates with the study by Chitra T [17]. In the study conducted by Sharma B et al. [1] to know the association of umbilical coiling index and perinatal outcome, Hypo coiling was observed in 15.67% cases and was associated with spontaneous preterm delivery(47.87%) with p value less than 0.001. Hyper coiling was also associated with spontaneous preterm delivery in 65.38%, but in our study no preterm delivery was seen in hyper coiled group.
The
study by Yun Sung Jo, Dong K J and GuiseraL [16]
in 226 patients, hypo coiled cords were present in 8.9% patients. The incidence
of preterm deliveries in hypo coiled group was significantly greater than the norm
coiled group. In this study the preterm delivery in the hypo coiled group was
36.4%, in the norm coiled group 7.7% and 16.7% in the hyper coiled group. Thus,
preterm deliveries are significantly associated with Hypo coiling of the cord
with a p value of 0.041 (Table 7, Graph 7).
Cord thickness, cross sectional area and aUCI has no correlation with mode of delivery. P value being 0.076, 0.857, 0.217 respectively in the study by Chitra T,Sushant Y S and Raghavan S [18]. Hyper coiling was present in 11.7% cases and preterm delivery was observed in 20.2% cases. This study also proved a statistically significant correlation between Hypo coiling and the preterm delivery with p value of 0.004.In another study by Monique W M Dee Last et al. [13] on umbilical cord coiling index in normal and complicated pregnancy, Hypo coiling of the cord was associated with spontaneous preterm delivery (OR 2.16, 95%C.I: 1.34-3.48).
5. Conclusion
Sonographic
evaluation of the umbilical cord parameters during anomaly scan is very
important but most neglected. It should be routinely performed along with other
fetal parameters. Any abnormality in the umbilical cord cross sectional area,
cord thickness or coiling index warrants a close monitoring of pregnancy.
Timely reorganization of any abnormality, close monitoring of pregnancy and
appropriate intervention can prevent untoward complications resulting in a safe
pregnancy and healthy baby.
Figure 1: Shows the
measurement technique of antenatal umbilical coiling index (a UCI) with doppler
shown as above.
Figure 2: Shows a
Transabdominal image on USG of an umbilical cord showing the cross-sectional
area measurement technique antenatal (In yellow calipers).
Figure 3: Shows a Transabdominal
USG image depicting the umbilical arterial and venous waveforms consistently
being normal in a 16-week-old fetus.
Figure 4: Shows three Transabdominal
USG images (A-C) depicting, A- transverse section of the triple vessel cord, B-
colorDoppler of the cord in longitudinal section & C- the insertion of the
cord into the abdominal wall.
Figure 5: Shows three Trans
abdominal USG images (A-C) depicting, A- hypo coiled cord, B- normoicoiled cord
& C- hyper coiled cord.
Graph 1: Distribution
according to cord thickness.
Graph 2: Distribution
according to cross sectional area of cord.
Graph 3: aUCI
distribution.
Graph 4: Comparison of
cord thickness, cross sectional area and aUCI in relation to NICU admission.
Graph 5: Comparison of
cord thickness, cross sectional area and aUCI in relation to MSAF.
Graph 6: Comparison of
cord thickness, cross sectional area and aUCI in relation to birth weight (kg).
Graph 7: Comparison of
cord thickness, cross sectional area in relation to mode of delivery.
|
No. of patients |
% |
<7 |
18 |
18.0 |
7-12 |
71 |
71.0 |
>12 |
11 |
11.0 |
Mean ± SD : 8.89±2.14 |
Table 1: Distribution according to cord thickness.
Cross sectional area in mm2 |
No. of patients |
% |
<20 |
17 |
17.0 |
20-30 |
47 |
47.0 |
≥30 |
36 |
36.0 |
Mean ± SD :25.03±7.48 |
Table 2: Distribution according to cross sectional area of cord.
aUCI |
No. of patients |
% |
<0.3 |
16 |
16.0 |
0.3-0.6 |
66 |
66.0 |
>0.6 |
18 |
18.0 |
Mean ±S.D : 0.44 ±0.15 |
Table 3: aUCI distribution.
Variables |
NICU |
Total |
P Value |
|
No |
Yes |
|||
Cord thickness |
9.07±2.05 |
6.88±2.17 |
8.89±2.14 |
0.005 |
Cross sectional area |
25.86±6.91 |
15.50±7.58 |
25.03±7.48 |
<0.001 |
aUCI |
0.44±0.15 |
0.41±0.22 |
0.44±0.15 |
0.556 |
Table 4: Comparison of cord thickness, cross sectional area and aUCI in relation to NICU admission.
Variables |
MSAF |
TOTAL |
P VALUE |
|
NO |
YES |
|||
Cord thickness |
8.91±2.18 |
8.80±1.99 |
8.89±2.14 |
0.834 |
Cross sectional area |
25.18±7.57 |
24.45±7.29 |
25.03±7.48 |
<0.700 |
aUCI |
0.41±0.13 |
0.57±0.18 |
0.44±0.15 |
<0.001** |
Table 5: Comparison of cord thickness, cross sectional area and aUCI in relation to MSAF.
Variables |
Birth Weight (kg) |
Total |
P Value |
|
<2.5 |
>2.5 |
|||
Cord thickness |
6.19±0.91 |
9.40±1.90 |
8.89±2.14 |
<0.001** |
Cross sectional area |
11.88±6.26 |
27.54±4.47 |
25.03±7.48 |
<0.001** |
aUCI |
0.28±0.16 |
0.47±0.13 |
0.44±0.15 |
<0.001** |
Table 6: Comparison of cord thickness, cross sectional area and aUCI in relation to birth weight (kg).
Variables |
Mode of delivery
|
TOTAL |
P VALUE |
|
FTND/PTVD |
LSCS |
|||
Cord thickness |
8.56±2.07 |
9.33±2.17 |
8.89±2.14 |
<0.076 |
Cross sectional area |
24.91±7.56 |
25.19±7.46 |
25.03±7.48 |
<0.857 |
aUCI |
0.42±0.15 |
0.46±0.16 |
0.44±0.15 |
<0.217 |
Table 7: Comparison of cord thickness, cross sectional area and aUCI in relation to mode of delivery.
- Bindu Sharma, Neelam Bhardwaj, Shashi Kumar Gupta, Pradeep Kumar Gupta, Asha Verma, et al. (2012) association of umbilical cord coiling index by colour doppler ultrasonography at 18-22 weeks of gestation and perinatal outcome. J Obstet Gynecol India 62: 650-654.
- Abdulrasul E A (2014) Umbilical coiling index as predictor of adverse perinatal outcome. Int. J Adv research 2: 101-7.
- De Laat,Monique WM, van Alderen, Elise D, FranxArie, et al. (2007) the umbilical coiling index in complicated pregnancy. Eur J Obstet Gynecol Reprod Biol 6: 357-358.
- PatilN
S, Kulkarni S R, Lohitashwa R (2013) umbilical cord coiling index and perinatal
outcome. J Clin Dia Res 7: 1675-7.
- Henry W(1954) Edmonds the spiral twists of the normal umbilical cord in twins and in singletons. Am J Obstet Gynecol 67: 102-120.
- Strong TH,Jarles DL, Vega JS, Feldman DB (1994) he umbilical coiling index. Am J Obstet Gynecol 170: 29-32.
- Sebire N J (2007) pathophysiological significance of abnormal umbilical cord coiling index. Ultrasound J Obstet Gynecol 30: 804-806.
- Degani S, Leibovich Z, Shapiro I, Gonen R, Ohel G (2001) Early 2nd trimester low umbilical cord coiling index predicts small for gestational age foetuses. J ultrasound Med 20: 1183-1188.
- Qureshi F, Jacques SM (1994) Marked segmental thinning of the umbilical cord vessels. Arch Pathol Lab Med 118: 828-830
- Predanic M., Perni S C (2005) absence of a relationship between umbilical cord thickness and coiling patterns.J Ultrasound Med 24: 1491-1496.
- Tahasembi M, Alighambari R (2011) evaluation of umbilical cord thickness, cross sectional area and coiling index as predictors of pregnancy outcome. Indian J Radiol Imaging 21:195-198.
- De Laat MW, Franx A, Bots M L, Visser GH, Nikkels P (2006) umbilical cord coiling index in normal and complicated pregnancies. Jobstet and Gyencol 107: 1049-1055.
- Kashanian M, Akbarian A, Kouhpayehzadeh J (2006) the umbilical cord coiling index and adverse perinatal outcome. Int J Obstet and Gynecol 95: 8-13.
- Gupta S, Faridi M M A, Krishnan J (2006) Umbilical coiling index. J Obstet Gynecol India 56: 315-319.
- Goynumer G,
Ozdemir A, Wetherilt L, Durukan B, Yayla M (2008) Umbilical cord thickness in
the first and early second trimester and perinatal outcome. J perinatal Med 36: 523-526.
- Yun Sung J, Dong K J, Guisera L (2011) The sonographic umbilical cord coiling in late second trimester of gestation and perinatal outcomes. Int J Med Sci 8: 594-598.
- Chitra T, Sushanth YS and Raghavan S (2012) Umbilical cord index as a marker of perinatal outcome. Obstet and Gynecol International 12: 201-207.
- Rakesh K Guptha, Amit mittal (2012) Prognostic indices for pregnancy outcome on ultrasound: a prospective study. Pak J Radio 22: 78-83.
- Snoor Jalal Mustafa, Abir Moheidin Said(2013) Association of umbilical coiling index in normal and complicatedpregnancies. Diyala J Med 5: 15-22.
- Kamolchanok Anusasananant, Sornpin Armarttasn, Budsaba Wiriyasirivaj (2014) The association between antenatal umbilical cord coiling index pattern and meconium stained amniotic fluid in gestational diabetes mellitus. Thai J Obstet and Gynecol 22: 67-73.
- Chandrakala
K. Analysis of literature signifying importance of umbilical cord coiling index
on perinatal outcome. South Amer J Med 2014: 911.
- Eze
CU (2014) Relationship between antenatal umbilical cord size and gestational
age among pregnant women in Egypt, Nigeria. African health sciences 14: 334-42.
- Chakrabatt
M, Ray S De, Roy D, Ghosh B M, Agarwal A (2014) Correlation of umbilical cord
thickness with fetal birth weight. A prospective study in rural Bengal. J Evol
Med and Den Sci 131: 70-4.
- McGraw
Hill (2010) Williams, implantation, embryogenesis and placental development in
William’s obstetrics, 23rd edition 61-62.
- Dutta
D C (2015) The placenta and fetal membranes in text book of obstetrics, 8th edition, Calcutta, New central book agency
pvt Ltd 44-45.